SPECIFICATION
MODEL
PLN-60-12PLN-60-15PLN-60-20PLN-60-24PLN-60-27PLN-60-36PLN-60-48DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE Note.6
CURRENT ADJ. RANGE Note.6LINE REGULATION LOAD REGULATION SETUP TIME VOLTAGE RANGE Note.5FREQUENCY RANGE POWER FACTOR
EFFICIENCY(Typ.)AC CURRENT
INPUT
INRUSH CURRENT(max.)LEAKAGE CURRENT WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION OTHERS
NOTE
PACKING
OVER CURRENT
SHORT CIRCUIT Note.4OVER VOLTAGE
OVER TEMPERATURE 12V 15V
20V 24V 27V 36V 48V 5A 4A 3A 2.5A 2.3A 1.7A 1.3A 0 ~ 5A 0 ~ 4A 0 ~ 3A 0 ~ 2.5A 0 ~ 2.3A 0 ~ 1.7A 0 ~ 1.3A 60W 60W 60W 60W 62.1W 61W 62.5W 2Vp-p 2.4Vp-p 1.8Vp-p 2.7Vp-p 2.7Vp-p 3.6Vp-p 4.6Vp-p 10%3% ~ -25%. Can be adjusted by internal potential meter SVR23.0%5.0%
1500ms / 230VAC 3000ms / 115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC 83%
84.5%
86.5%
86.5%
87%
87%
88%
13.8 ~ 16V 17.5 ~ 21V 22.8 ~ 25V 28 ~ 32V
31 ~ 35V
41 ~ 46V
54 ~ 60V
0.8A/115VAC 0.4A/230VAC 40A/230VAC <0.75mA / 240VAC Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
-30 ~ +50(Refer to output load derating curve)20 ~ 95% RH non-condensing
-40 ~ +80, 10 ~ 95% RH 0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X,Y, Z axes
497.8Khrs min. MIL-HDBK-217F (25)
181*61.5*35mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
Direct connecting to LEDs is not suggested for models with RIPPLE & NOISE >10% and using additional drivers is highly recommended.3. Tolerance : includes set up tolerance, line regulation and load regulation.4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
6. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
7. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.
0.5Kg; 24pcs/13Kg/0.75CUFT
60W Single Output LED Power Supply
Universal AC input / Full range
Fully isolated plastic case with IP64 level
Built-in constant current limiting circuit with adjustable OCP level Protections: Short circuit / Overload / Over voltage / Over temperature Built-in active PFC function
IP64 design for indoor or outdoor installations UL1310 Class 2 power unit Cooling by free air convection 100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting 2 years warranty
Features :
PLN-60
series
RIPPLE & NOISE (max.)Note.2VOLTAGE TOLERANCE Note.3ENVIRONMENT SAFETY &EMC PROTECTION 95
10
(TSW1) detect on heatsink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down File Name:PLN-60-SPEC 2009-03-04
SAFETY STANDARDS WITHSTAND VOLTAGE
ISOLATION RESISTANCE I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH HARMONIC CURRENT
EMS IMMUNITY
Compliance to EN55022 (CISPR22) Class B
EN55015,Compliance to Class C (75% load) ; EN61000-3-3EN61000-3-2Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024,EN61547, light industry level, criteria A EMI CONDUCTION & RADIATION UL1310 Class 2,CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved TUV EN61347-1, EN61347-2-13,130% (max)
95 ~ 110%
Protection type :Shut down o/p voltage, re-power on to recover
IP64
( for 48V only)( except for 48V )
F
M M 110
LPS
SELV
EQUIVALENT
10.5 ~15V 14 ~ 20V 16.8 ~24V 18.9 ~27V 25.2 ~ 36V 33.6 ~ 48V 8.4 ~ 12V
CONSTANT CURRENT REGION Note.7Can be adjusted by internal potential meter SVR111 ~ 13V
13.8 ~ 16.2V
18 ~ 22V
22 ~ 26V
25 ~ 30V
32.5 ~ 39V
43.6 ~ 51.8V
Mechanical Specification
File Name:PLN-60-SPEC 2009-03-04
Case No.960A
Unit:mm
FG (Green/Yellow)
300
300
DC OUT
AC IN
6.26
6.26
181
18AWG 2C
21.25
61.5
21.25
35
+V(Red)-V(Black)
2-R2.5
18AWG 3C
Ta:25
Derating Curve Static Characteristics
AMBIENT TEMPERATURE ()L O A D (%)
-30-25-50153040506020
4060
80100INPUT VOLTAGE (V) 60Hz
90100125135145155165175180200230264
100908070
605040
L O A D (%)
(HORIZONTAL)
fosc : 90KHz(115VAC)
120KHz(230VAC)
DETECTION PWM & PFC CIRCUIT
O.L.P.
EMI FILTER
RECTIFIERS
FILTER
&RECTIFIERS
+V -V
I/P
FG
CONTROL
O.V.P.
&
O.C.P.
50
AC/L(Brown)AC/N(Blue)
POWER SWITCHING
60W Single Output LED Power Supply
PLN-60
series
Block Diagram
SVR1
SVR2
Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2
shown in the diagram.
Output voltage adjustment Output current adjustment
SVR1SVR2