文档视界 最新最全的文档下载
当前位置:文档视界 › 300MW机组凝结水溶氧分析

300MW机组凝结水溶氧分析

300MW机组凝结水溶氧分析
300MW机组凝结水溶氧分析

#11机凝结水溶氧高原因分析

#11机自B级检修后,多次发生复水溶氧超标问题,针对这一缺陷,我分公司做了大量的工作,但效果不是太明显,现对前一段时间所做的工作和今后的工作安排向上级部门做一简要的汇报。

一、缺陷描述和所做的工作

11月18日3点#11机溶氧突然变大60ug/L,值班人员检查#11机凝结水泵未见异常,检查机械密封密封水压力正常,把所有密封处都涂一遍黄油,继续观察#11机溶氧。19日溶氧一直在55ug/L左右。19日晚解列#11机#112凝结水泵查漏,解列前#11机溶氧53ug/L,解列后溶氧变到65ug/L,#112凝结水泵憋压到1.8MPa,发现泵地角有两条螺丝漏水,重新紧螺丝,其它未见异常。恢复#112凝结水泵,溶氧变到52ug/L。20日晚解列#111凝结水泵,解列前#11机溶氧62ug/L,解列后溶氧100ug/L,#111凝结水泵憋压到1.8MPa,泵地角有两条螺丝漏,紧固螺丝,恢复#111凝结水泵,溶氧到62ug/L。21日白天#11机溶氧55ug/L,调整密封水到1.0MPa,紧热井人孔,紧#111、#112凝结水泵地角螺丝,热井水位计所有接口涂黄油,水封筒放水接口涂黄油,#112机械密封涂黄油。300MW负荷时,溶氧35ug/L,继续观察最小到22ug/L,晚上又变大到55ug/L。经过微机纪录分析,复水器补水可以影响复水溶氧20 ug/L左右。12月7日对复水采样点由精处理出口改到复水泵出口(与#10同),但效果不明显。后又对热井水位以下的负压部分进行多次查漏。

12月21日又对#11机负压部分进行了查堵漏,堵漏部分包括真

空破坏门,热井放水门,汽封冷却器疏水水封筒放水门及法兰,汽侧人孔,水位计上下联通门,凝结水泵入口滤网和入口门,入口滤网压差表放水门,小机密封水回水水封筒至凝汽器手动门调整(关小到小机处不漏水)其补水门调整(开大),管道扩容器疏水至凝汽器手动门校严等

分析其他原因:小机汽封泄露、以及其他与汽侧相关设备漏空引起真空降低,冬季供热负荷大补水量大,因冬季水温低造成凝汽器过冷度增加等,建议联系电研所对机组负压部位进行查漏(包括负荷低时由正压变为负压的抽汽管道)。

溶解氧分析仪产品说明及其分类特点

溶解氧分析仪产品说明及其分类特点

空气中的分子态氧溶解在水中称为溶解氧。水中的溶解氧的含量与空气中氧的分压、水的温度都有密切关系。在自然情况下,空气中的含氧量变动不大,故水温是主要的因素,水温愈低,水中溶解氧的含量愈高。溶解于水中的分子态氧称为溶解氧,通常记作DO,用每升水里氧气的毫克数表示。 水里的溶解氧被消耗,要恢复到初始状态,所需时间短,说明该水体的自净能力强,或者说水体污染不严重。否则说明水体污染严重,自净能力弱,甚至失去自净能力。 二、如何选择聚创的溶解氧仪? 1、先确认使用场所及环境 (1)实验室台式:RJY-1、JPSJ-605、JPSJ-605F (2)野外笔式及便携式:RDB20、RJY-1A、AZ8403、JPB-607A、JPBJ-608、JC-DO2000 (3)现场实时监测:JC-DO3000、JC-DO5000、JC-DO6000 2、实验室台式 (1)RJY-1:比色测定,可以粗略测量溶解氧 (2)JPSJ-605、JPSJ-605F:探头测定溶解氧,精度高 3、野外笔式及便携式 (1)RDB20:用于粗略野外检测,偏差较大 (2)RJY-1A:野外便携式测定,比色方法,精度一般 (3)AZ8403:台湾衡欣品牌,测定精准

(4)JPB-607A:探头测定,自动温补,可以显示溶解氧和温度 (5)JPBJ-608:探头测定,自动温补,可以显示浓度、饱和度、温度 (6)JC-DO2000:探头测定,主要测定微量溶解氧 4、现场实时监测 (1)JC-DO3000:在线监测,测定常量溶解氧,可定制(2)JC-DO5000:在线监测,测定微量溶解氧;可定制(3)JC-DO6000:在线监测,荧光法测定常量溶解氧

凝结水溶氧超标的原因及处理

凝结水溶氧超标的原因 及处理 集团企业公司编码:(LL3698-KKI1269-TM2483-LUI12689-ITT289-

凝结水溶氧超标的原因及处理1备用泵轴封失效引起凝结水溶氧超标 1.1取掉凝泵水封环埋下了隐患 2004-07-16,2号机凝结水溶氧达到40~60礸/L,现场多次查漏未果,最后查阅该泵检修记录时发现,盘根室内的水封环被取掉了(原因是当时凝泵盘根处甩水严重,试将水封环取掉换为盘根,以增强密封,减小盘根处漏量)。凝结水泵盘根密封水工作原理见图1。 从图1可以看出:在水封环换为盘根后,盘根密封水进水口就被盘根堵塞了,之所以一直未发生凝结水溶氧超标,是因为该处盘根与轴套紧密接触,隔绝了空气,而当轴套经长时间运行磨损后,盘根与轴套出现间隙,致使空气从压兰吸入泵体内,引起凝结水溶氧超标。

针对这一原因,分2步进行了处理。 第1步,为了满足机组稳定运行的要求,临时将B凝泵密封水回水门关小,以减少从凝泵压兰处漏入的空气。此方法取得了很好的效果,凝结水溶氧从50礸/L降至7礸/L。 第2步,利用机组小修机会,彻底更换盘根、轴套、水封环。此后,凝结水溶氧正常。 1.2备用泵盘根密封水压力不足

该公司凝结水系统正常运行时,备用凝泵盘根密封水取自外供除盐水,而其回水则回到凝泵入口,这样不断地给机组补水,超出机组需求的补水被排掉,造成浪费,不符合电厂节能降耗的要求,为此利用机组临停,对3号机凝结水管路进行了改造。改造前后凝泵盘根密封/冷却水系统见图2。 图2改造前、后凝泵盘根密封/冷却水系统 改造之后不再有浪费水的现象。2005年2月出现凝结水溶氧超标,达到80~90礸/L。对比凝泵密封水改造前后的系统布置,分析认为,由于改造后A凝泵(运行泵)自密封水同时供给2台泵的盘根密封/冷却用水,而导致供给B泵(备用泵)盘根密封水的压力下降,引起漏空溶氧。

荧光光谱分析仪工作原理

X 荧光光谱分析仪工作原理 用x 射线照射试样时,试样可以被激发出各种波长得荧光x 射线,需要把混合得x 射线 按波长(或能量)分开,分别测量不同波长(或能虽:)得X 射线得强度,以进行左性与定疑 分析,为此使用得仪器叫X 射线荧光光谱仪。由于X 光具有一泄波长,同时又有一立能量, 因此,X 射线荧光光谱仪有两种基本类型:波长色散型与能量色散型。下图就是这两类仪器 得原理图. 用X 射线照射试样时,试样可以被激发出各种波长得荧光X 射线,需要把混合得X 射 线按波长(或能疑)分开,分别测量不同波长(或能量)得X 射线得强度,以进行定性与左疑 分析,为此使用得仪器叫X 射线荧光光谱仪。由于X 光具有一左波长,同时又有一左能量, 因此,X 射线荧光光谱仪有两种基本类型:波长色散型与能量色散型。下图就是这两类仪器 得原理图。 (a )波长色散谱仪 (b )能虽色散谱仪 波长色散型和能量色散型谱仪原理图 现将两种类型X 射线光谱仪得主要部件及工作原理叙述如下: X 射线管 酥高分析器 分光晶体 计算机 再陋电源

丝电源 灯丝 电了悚 X则线 BeiV 輪窗型X射线管结构示意图 两种类型得X射线荧光光谱仪都需要用X射线管作为激发光源?上图就是X射线管得结构示意图。灯丝与靶极密封在抽成貞?空得金属罩内,灯丝与靶极之间加高压(一般为4OKV), 灯丝发射得电子经高压电场加速撞击在靶极上,产生X射线。X射线管产生得一次X射线, 作为激发X射线荧光得辐射源.只有当一次X射线得波长稍短于受激元素吸收限Imi n时,才能有效得激发出X射线荧光?笥?SPAN Ian g =EN-U S >lmin得一次X射线其能量不足以使受激元素激发。 X射线管得靶材与管工作电压决立了能有效激发受激元素得那部分一次X射线得强度。管 工作电压升高,短波长一次X射线比例增加,故产生得荧光X射线得强度也增强。但并不就是说管工作电压越髙越好,因为入射X射线得荧光激发效率与苴波长有关,越靠近被测元素吸收限波长,激发效率越髙。A X射线管产生得X射线透过彼窗入射到样品上, 激发岀样品元素得特征X射线,正常工作时,X射线管所消耗功率得0、2%左右转变为X 射线辐射,其余均变为热能使X射线管升温,因此必须不断得通冷却水冷却靶电极。 2、分光系统 第?准讥器 平面晶体反射X线示意图 分光系统得主要部件就是晶体分光器,它得作用就是通过晶体衍射现彖把不同波长得X射线分开.根据布拉格衍射左律2d S in 0 =n X ,当波长为X得X射线以0角射到晶体,如果晶面间距为d,则在出射角为0得方向,可以观测到波长为X =2dsi n 0得一级衍射及波长为X/2, X /3 ------ ―等髙级衍射。改变()角,可以观测到另外波长得X

凝结水溶氧超标的原因分析及处理

凝结水溶氧超标的原因分析及处理 本文重点分析了火力发电厂机组常见的凝结水溶氧超标的原因,论述了凝结水溶氧超标的危害,并针对各种超标原因提出了处理办法,对各火力发电厂凝结水溶氧超标的问题提供了可行的方法,具有一定的借鉴作用。 标签:溶氧超标危害办法 Cause analysis and treatment for the dissolved oxygen in the feedwater deaerator exceed the standard Shen Zhibin (Inner Monglia Datang International Tuoketuo Power Generation Co.Ltd.,Tuoketuo 010206,China) Abstract:This paper focuses on the analysis of the thermal power plant unit common condensation of excessive dissolved oxygen in water,discusses the setting and the harm of excessive dissolved oxygen in water,and for a variety of causes of excessive solutions are proposed,for the thermal power plant condensate water dissolved oxygen overproof problems provides a feasible method,which has a certain reference. Key words:Dissolved oxygen Exceed the standard Harm method 引言 火电厂机组凝结水溶氧是电厂化学监督的的重要指标之一。凝结水溶氧大幅超标或长期不合格,会造成锅炉、管道、设备的高温腐蚀,降低回热设备的换热效率,缩短管道和设备的使用寿命,严重威胁机组安全经济运行,所以降低凝结水溶氧具有重要和深远的现实意义。火力发电厂水汽化学监督导则要求超高压发电机组在正常运行时,凝结水溶氧合格标准为小于30μg/l,小于20μg/l为期望值。机组正常运行时凝汽器处于真空状态,凝结水应该是合格的,但由于诸多原因导致国内许多供热机组普遍存在凝结水溶氧超标问题。 一、凝结水溶氧超标概况 某电厂2*300MW机组为湿冷纯凝汽轮发电机组,于2007年12月份投产,2012年01月开始转为自备电厂,开始对外供热,供热量200t/h。凝结水溶氧的控制方法主要采用凝汽器真空除氧及加联氨方式。2台300MW机组开始供热后,凝结水溶氧这个指标经常处于超标运行状态,超过50μg/l的次数达到15次/月。为了彻底消除溶氧超标,该厂从凝结水溶氧超标常见的原因进行分析,并针对各个原因进行查找并采取一定的措施,本文重点对该厂的查找过程及查找出溶氧超

各种仪器分析的基本原理及谱图表示方法!!!紫外吸收光谱UV分析

各种仪器分析的基本原理及谱图表示方法!!! 紫外吸收光谱UV 分析原理:吸收紫外光能量,引起分子中电子能级的跃迁谱图的表示方法:相对吸收光能量随吸收光波长的变化提供的信息:吸收峰的位置、强度和形状,提供分子中不同电子结构的信息荧光光谱法FS 分析原理:被电磁辐射激发后,从最低单线激发态回到单线基态,发射荧光谱图的表示方法:发射的荧光能量随光波长的变化提供的信息:荧光效率和寿命,提供分子中不同电子结构的信息红外吸收光谱法IR 分析原理:吸收红外光能量,引起具有偶极矩变化的分子的振动、转动能级跃迁谱图的表示方法:相对透射光能量随透射光频率变化提供的信息:峰的位置、强度和形状,提供功能团或化学键的特征振动频率拉曼光谱法Ram 分析原理:吸收光能后,引起具有极化率变化的分子振动,产生拉曼散射谱图的表示方法:散射光能量随拉曼位移的变化提供的信息:峰的位置、强度和形状,提供功能团或化学键的特征振动频率核磁共振波谱法NMR 分析原理:在外磁场中,具有核磁矩的原子核,吸收射频能量,产生核自旋能级的跃迁谱图的表示方法:吸收光能量随化学位移的变化提供的信息:峰的化学位移、强度、裂分数和偶合常数,提供核的数目、所处化学环境和几何构型的信息电子顺磁共振波谱法ESR 分析原理:在外磁场中,分子中未成对电子吸收射频能量,产生电子自旋能级跃迁谱图的表示方法:吸收光能量或微分能量随磁场强度变化提供的信息:谱线位置、强度、裂分数目和超精细分裂常数,提供未成对电子密度、分子键特性及几何构型信息 质谱分析法MS 分析原理:分子在真空中被电子轰击,形成离子,通过电磁场按不同m/e 分离 谱图的表示方法:以棒图形式表示离子的相对峰度随m/e 的变化提供的信息:分子离子及碎片离子的质量数及其相对峰度,提供分子量,元素组成及结构的信息气相色谱法GC 分析原理:样品中各组分在流动相和固定相之间,由于分配系数不同而分离谱图的表示方法:柱后流出物浓度随保留值的变化提供的信息:峰的保留值与组分热力学参数有关,是定性依据;峰面积与组分含量有关反气相色谱法IGC 分析原理:探针分子保留值的变化取决于它和作为固定相的聚合物样品之间的相互作用力谱图的表示方法:探针分子比保留体积的对数值随柱温倒数的变化曲线提供的信息:探针分子保留值与温度的关系提供聚合物的热力学参数裂解气相色谱法PGC 分析原理:高分子材料在一定条件下瞬间裂解,可获得具有一定特征的碎片谱图的表示方法:柱后流出物浓度随保留值的变化提供的信息:谱图的指纹性或特征碎片峰,表征聚合物的化学结构和几何构型凝胶色谱法GPC 分析原理:样品通过凝胶柱时,按分子的流体力学体积不同进行分离,大分子先流出谱图的表示方法:柱后流出物浓度随保留值的变化提供的信息:高聚物的平均分子量及其分布热重法TG 分析原理:在控温环境中,样品重量随温度或时间变化谱图的表示方法:样品的重量分数随温度或时间的变化曲线提供的信息:曲线陡降处为样品失重区,平台区为样品的热稳定区热差分析DTA 分析原理:样品与参比物处于同一控温环境中,由于二者导热系数不同产生温差,记录温度随环境温度或时间的变化 谱图的表示方法:温差随环境温度或时间的变化曲线提供的信息:提供聚合物热转变温度及各种热效应的信息示差扫描量热分析DSC 分析原理:样品与参比物处于同一控温环境中,记录维持温差为零时,所需能量随环境温度或时间的变化 谱图的表示方法:热量或其变化率随环境温度或时间的变化曲线提供的信息:提供聚合物热转变温度及各种热效应的信息静态热―力分析TMA 分析原理:样品在恒力作用下产生的形变随温度或时间变化谱图的表示方法:样品形变值随温度或时间变化曲线提供的信息:热转变温度和力学状态

JPBJ-608型便携式溶解氧测定仪操作规程

JPBJ-608型便携式溶解氧测定仪操作规程 1.启动 插上电源,按下“on/off”键,仪器液晶将全显,约两秒后仪器自动进入测量状态。 2.溶解氧电极测量 将氧电极用蒸馏水清洗后插入被测溶液,仪器开机后即可进行测量。仪器在测量状态下同时计算溶解氧浓度、饱和度和电极电流值、可以按“DO/I/%”键进行测量状态切换显示。 3.溶解氧电极的标定 3.1、零氧标定 将溶解氧电极放入5%的新鲜配制的亚硫酸钠溶液中,在仪器处于测量状态下,按“模式/测量”键,仪器即进入模式选择状态,按“▲/mgL-1/%”键或“▼/贮存”键选择“ZERO”(显示在液晶左下角),按“确定/打印”键仪器即进入零氧校准功能状态。 此时,仪器显示当前的溶解氧值,按“▲/mgL-1/%”键依次切换显示溶解氧浓度值、饱和度值和电极电流值,待读数稳定后按“确定/打印”键,仪器显示“0.00mg/L”,约5秒后仪器自动退出“ZERO”状态,进入模式选择状态,零氧校准结束。 3.2、满度标定 在仪器处于测量状态下,按“模式/测量”键,仪器即进入模式选择状态,按“▲/mgL-1/%”键或“▼/贮存”键选择“FULL”(显示在液晶左下角),按“确定/打印”键仪器即进入满度校准功能状态。 此时,仪器显示当前的溶解氧值,按“▲/mgL-1/%”键依次切换显示氧浓度值、氧饱和度值和电极电流值,把溶解氧电极从溶液中取出,用水冲洗干净,用滤纸小心吸干薄膜表面的水分,并放入盛有蒸馏水容器(如三角烧瓶、高脚烧杯中)靠近水面的空气上或者放入空气中,但电极表面不能占上水滴,待读数稳定后按“确定/打印”键,仪器显示当前温度下的饱和溶解氧值,约5秒后仪器自动退出“FULL”状态,进入模式选择状态,满度校准结束。 3.3、盐度标定 溶解氧值与盐度值有关,仪器内部预设的盐度值为0.0 g/L,测量前应选择合适的盐度值。 3.4、气压标定 仪器测得的溶解氧值与大气压值有关,仪器内部预设的大气压值为101.3Pa,测量前应选择合适的气压值。 4.JPBJ-608型便携式溶解氧测定仪 使用完毕,如需要存储的数据应按“贮存”键保存,此时按仪器的“开/关”键关闭仪器。

溶解氧测试仪的原理

溶解氧测试仪的原理 水体溶解氧的检测方法及原理 Elemtron公司溶解氧测试仪 标准型溶解氧测试仪 溶解氧测试仪的产品 [编辑本段]溶解氧测试仪的原理 在污水处理过程中,通过增加污水中的氧含量使污染物通过活化泥浆被分解出来,达到污水净化的目的,测量氧含量有助于确定最佳的净化方法和最经济的曝气池配置。在生物发酵过程中氧含量的测量数据可对工艺过程进行指导,如判断发酵过程的临界氧浓度、发酵罐的供氧能力以及菌体的活性和菌体的生长量等,并根据发酵时的供氧和需氧变化来指导补料操作。 一、溶解氧分析仪测量原理氧在水中的溶解度取决于温度、压力和水中溶解的盐。溶解氧分析仪传感部分是由金电极(阴极)和银电极(阳极)及氯化钾或氢氧化钾电解液组成,氧通过膜扩散进入电解液与金电极和银电极构成测量回路。当给溶解氧分析仪电极加上 0."6~ 0.8V的极化电压时,氧通过膜扩散,阴极释放电子,阳极接受电子,产生电流,整个反应过程为: 阳极Ag+Cl→AgCl+2e-阴极O2+2H2O+4e→4OH-根据法拉第定律: 流过溶解氧分析仪电极的电流和氧分压成正比,在温度不变的情况下电流和氧浓度之间呈线性关系。 二、溶解氧含量的表示方法溶解氧含量有3种不同的表示方法: 氧分压(mmHg);百分饱和度(%);氧浓度(mg/L或10-6),这3种方法本质上没什么不同。

(1)分压表示法: 氧分压表示法是最基本和最本质的表示法。根据Henry定律可得, P=(Po2+P H2O )3 0."209,其中,P为总压;Po2为氧分压(mmHg);P H2O为水蒸气分压; 0.209为空气中氧的含量。 (2)百分饱和度表示法: 由于曝气发酵十分复杂,氧分压不能计算得到,在此情况下用百分饱和度的表示法是最合适的。例如将标定时溶解氧定为100%,零氧时为0%,则反应过程中的溶解氧含量即为标定时的百分数。 (3)氧浓度表示法: 根据Henry定律可知氧浓度与其分压成正比,即: C=Po23a,其中C为氧浓度(mg/L);Po2为氧分压(mmHg);a为溶解度系数(mg/mmHg2L)。溶解度系数a不仅与温度有关,还与溶液的成分有关。对于温度恒定的水溶液,a为常数,则可测量氧的浓度。氧浓度表示法在发酵工业中不常用,但在污水处理、生活饮用水等过程中都用氧浓度来表示。 三、影响溶解氧测量的因素氧的溶解度取决于温度、压力和水中溶解的盐,另外氧通过溶液扩散比通过膜扩散快,如流速太慢会产生干扰。 1.温度的影响由于温度变化,膜的扩散系数和氧的溶解度都将发生变化,直接影响到溶氧电极电流输出,常采用热敏电阻来消除温度的影响。温度上升,扩散系数增加,溶解度反而减小。温度对溶解度系数a的影响可以根据Henry 定律来估算,温度对膜扩散系数β可以通过阿仑尼乌斯定律来估算。 (1)氧的溶解度系数: 由于溶解度系数a不仅受温度的影响,而且受溶液的成分的影响。

分析凝结水溶解氧偏高的原因

摘要 在火电厂机组运行正常情况下,凝结水溶解氧量是合格的,但是因为许多原因,导致凝结水溶解氧偏高,使机组不能安全稳定的运行,所以必须对凝结水溶解氧偏高的原因进行分析并且使其溶氧量达到标准值。 本文从凝结水系统入手,通过介绍该系统的组成,得出凝结水在整个系统中的流程。而凝结水在循环使用中,不可避免地含有腐蚀物和杂质,而随着电厂机组容量的增大,对水质要求提高,又必须对凝结水进行精处理。然后通过介绍凝结水精处理系统,分析凝结水受污染的原因以及精处理系统需经过过滤和除盐两部分,去除金属腐蚀产物和悬浮杂质以及溶解盐类,但是凝结水溶解氧量偏高所产生的危害却未能消除。接着介绍凝结水溶解氧量偏高所带来的危害,以及可能引起溶解氧量偏高的原因和解决措施,最后以蒙达发电公司和山西武乡和信发电公司为例,根据这两个电厂溶解氧偏高原因的分析以后,都采取相应的有效措施,来降低溶解氧以达到标准值,使机组可以正常运行,这样既提高了资源的利用率,也减少了生产运行成本。 关键词:凝结水;精处理;溶解氧;

Abstract Coal-fired power plants operation in normal circumstances,condensate dissolved oxygen is qualified, because of many reasons, resulting in condensate dissolved oxygen is high , so that units can not be a safe and stable operation, it must be reasons for the high condensate analysis of dissolved oxygen and let dissolved oxygen reach standard value. This paper introduces condensed water from the system ,according to introducing the composition of the system obtained in the condensate flow in the system.The condensation of water recycling, inevitably contain corrosive and impurities, and with the power unit capacity increases, improve water quality requirements, but also must be polishing condensate.Then by introducing the condensate polishing system, the analysis of the causes of contaminated condensate polishing system, and should be filtered and the desalination of two parts, the removal of metal corrosion products and suspended impurities and dissolved salts, but high levels of dissolved oxygen of the harm in the condensate is not removed.Then introduced the high levels of dissolved oxygen in the condensate harm, and may cause high levels of dissolved oxygen causes and solutions,. Finally,Mengda power generation companies and power companies and Xinhe of Shanxi Wuxiang example, according to these two causes of the high dissolved oxygen plant, after they take appropriate and effective measures to reduce the dissolved oxygen to meet the standard value, the unit can be Normal operation, this not only improves the resource utilization, but also reduce the operating costs of production. Keywords: Condensate; polishing; dissolved oxygen;

频谱分析仪的原理及应用

频谱分析仪的原理及应用 (远程互动方式) 一、实验目的: 1、熟悉远程电子实验系统客户端程序的操作,了解如何控制远地服务器主机,操作与其连接的电子综合实验板和PCI-1200数据采集卡,具体可参照实验操作说明。 2、了解FFT 快速傅立叶变换理论及数字式频谱分析仪的工作原理,同时了解信号波形的数字合成方法以及程控信号源的工作原理。 3、在客户端程序上进行远程实验操作,由程控信号源分别产生正弦波、方波、三角波等几种典型电压波形,并由数字频谱分析仪对这几种典型电压波形进行频谱分析,并对测量结果做记录。 二、实验原理: 1、理论概要 数字式频谱分析仪是通过A/D 采样器件,将模拟信号转换为数字信号,传给微处理器系统或计算机来处理和显示,与模拟仪器相比,数据的量化更精确,而且很容易实现存储、传输、控制等智能化的功能。电压测量的分辨率取决于A/D 采样器件的位数,例如12位A/D 采样的分辨率是1/4096。在对交流信号的测量中,根据奈奎斯特采样定理,采样速率必须是信号频率的两倍以上,采样频率越高,时间轴上的信号分辨力就越高,所获得的信号就越接近原始信号,在频谱上展现的频带就越宽。 本实验系统基于虚拟仪器构建,数字频谱分析仪是通过PCI-1200数据采集卡来实现的。通过虚拟仪器软件提供的网络通信功能,实现客户端与服务器之间的远程通信。由客户端程序发出操作请求,由服务器接受并按照要求控制硬件实验系统,然后将采集到的实验数据发给客户端,由客户端程序进行处理。 频谱分析仪是在频域进行信号分析测量的仪器之一,它采用滤波或傅立叶变换的方法,分析信号中所含各个频率份量的幅值、功率、能量和相位关系。频谱仪按工作原理,大致可分为滤波法和计算法两大类,本实验所用的数字频谱分析仪采用的是计算法。 计算法频谱分析仪的构成如图1所示: 图1 计算法频谱分析仪构成方框图 数据采集部分由数据采集部分由抗混低通滤波(LP )、采样保持(S/H )和模数转换(A/D )几个部分组成。 数字信号处理(DSP )部分的核心是FFT 运算。 有限离散序列Xn 和它的频谱X m 之间的傅立叶变换可表示如下: N-1 nm X m = ∑ Xn ·W N n=0 -j2π/N 式中W N = C n,m = 0,1,……,N-1 1 N-1 -nm Xn = - ∑ X m ·W N N m=0 X m 有N 个复数值,由它可获得振幅和相位谱∣X m ∣,φm 。由于时间信号Xn 总是实函数,X m 的N 个值的前后半部分共轭对称。 由于数据采集进行的是有限时间内的信号采集,而不是无限时间信号,在进行FFT 变

溶解氧分析仪安全操作规程示范文本

溶解氧分析仪安全操作规 程示范文本 In The Actual Work Production Management, In Order To Ensure The Smooth Progress Of The Process, And Consider The Relationship Between Each Link, The Specific Requirements Of Each Link To Achieve Risk Control And Planning 某某管理中心 XX年XX月

溶解氧分析仪安全操作规程示范文本使用指引:此操作规程资料应用在实际工作生产管理中为了保障过程顺利推进,同时考虑各个环节之间的关系,每个环节实现的具体要求而进行的风险控制与规划,并将危害降低到最小,文档经过下载可进行自定义修改,请根据实际需求进行调整与使用。 1 操作规程 1.1开机 接通电源,按“开/关”键打开显示屏,使该仪器处于 测量状态。 1.2标定 标定流程: (1)将电极从流量池中取出。 (2)用纯净水冲洗干净电极。 (3)用软纸巾轻轻吸干电极体和电极膜表面的水珠。 (4)将电极在空气中放置3~5分钟。 (5)按照自动标定和零点标定提示进行标定。 (6)标定后的电极可重新放入流量池进行测量。

1.3测量 连接样品的进水管,被测量样品通过进水口流入流量池,然后通过出水口流出;显示屏的测量值开始很大,然后逐渐减小,最后达到稳定值,即测量结果。 1.4存储数据 2 注意事项 (1)仪器具有防水结构,但不能浸入水中使用。 (2)仪器接头不能接触水、污物等。 (3)不要用手或硬物触及电极膜表面。 (4)当显示“电池电压低”时,要及时给电池充电。 (5)仪器不用时应确保关机。 请在此位置输入品牌名/标语/slogan Please Enter The Brand Name / Slogan / Slogan In This Position, Such As Foonsion

溶解氧分析仪安全操作规程(最新版)

( 操作规程 ) 单位:_________________________ 姓名:_________________________ 日期:_________________________ 精品文档 / Word文档 / 文字可改 溶解氧分析仪安全操作规程(最 新版) Safety operating procedures refer to documents describing all aspects of work steps and operating procedures that comply with production safety laws and regulations.

溶解氧分析仪安全操作规程(最新版) 1操作规程 1.1开机 接通电源,按“开/关”键打开显示屏,使该仪器处于测量状态。 1.2标定 标定流程: (1)将电极从流量池中取出。 (2)用纯净水冲洗干净电极。 (3)用软纸巾轻轻吸干电极体和电极膜表面的水珠。 (4)将电极在空气中放置3~5分钟。 (5)按照自动标定和零点标定提示进行标定。 (6)标定后的电极可重新放入流量池进行测量。 1.3测量

连接样品的进水管,被测量样品通过进水口流入流量池,然后通过出水口流出;显示屏的测量值开始很大,然后逐渐减小,最后达到稳定值,即测量结果。 1.4存储数据 2注意事项 (1)仪器具有防水结构,但不能浸入水中使用。 (2)仪器接头不能接触水、污物等。 (3)不要用手或硬物触及电极膜表面。 (4)当显示“电池电压低”时,要及时给电池充电。 (5)仪器不用时应确保关机。 云博创意设计 MzYunBo Creative Design Co., Ltd.

溶解氧对发酵的影响及其控制

溶解氧对发酵的影响及其控制 1 溶解氧对发酵的影响 溶氧是需氧发酵控制最重要的参数之一。由于氧在水中的溶解度很小,在发酵液中的溶解度亦如此,因此,需要不断通风和搅拌,才能满足不同发酵过程对氧的需求。溶氧的大小对菌体生长和产物的形成及产量都会产生不同的影响。如谷氨酸发酵,供氧不足时,谷氨酸积累就会明显降低,产生大量乳酸和琥珀酸。 1.1 溶氧量在发酵的各个过程中对微生物的生长的影响是不同的 改变通气速率发酵前期菌丝体大量繁殖,需氧量大于供氧,溶氧出现一个低峰。在生长阶段,产物合成期,需氧量减少,溶氧稳定,但受补料、加油等条件大影响。补糖后,摄氧率就会增加,引起溶氧浓度的下降,经过一段时间以后又逐步回升并接近原来的溶解氧浓度。如继续补糖,又会继续下降,甚至引起生产受到限制。发酵后期,由于菌体衰老,呼吸减弱,溶氧浓度上升,一旦菌体自溶,溶氧浓度会明显上升。 1.2 溶氧对发酵产物的影响 对于好氧发酵来说,溶解氧通常既是营养因素,又是环境因素。特别是对于具有一定氧化还原性质的代谢产物的生产来说,DO的改变势必会影响到菌株培养体系的氧化还原电位,同时也会对细胞生长和产物的形成产生影响。 在黄原胶发酵中,虽然发酵液中的溶氧浓度对菌体生长速率影响不大,但是对菌体浓度达到最大之后的菌体的稳定期的长短及产品质量却有着明显的影响。

需氧微生物酶的活性对氧有着很强的依赖性。谷氨酸发酵中,高溶氧条件下乳酸脱氢酶(LDH)活性明显比低溶氧条件下的LDH酶活要低,产酸中后期谷氨酸脱氢酶(GDH)的酶活下降很快,这可能是由于在高溶氧条件下,剧烈的通气和搅拌加剧了菌体的死亡速度和发酵活性的衰减。 DO值的高低还会改变微生物代谢途径,以致改变发酵环境甚至使目标产物发生偏离。研究表明,L-异亮氨酸的代谢流量与溶氧浓度有密切关系,可以通过控制不同时期的溶氧来改变发酵过程中的代谢流分布,从而改变Ile等氨基酸合成的代谢流量。 2 溶氧量的控制 对溶解氧进行控制的目的是把溶解氧浓度值稳定控制在一定的期望值或范围内。在微生物发酵过程中,溶解氧浓度与其它过程参数的关系极为复杂,受到生物反应器中多种物理、化学和微生物因素的影响和制约。从氧的传递速率方程也可看出,对DO值的控制主要集中在氧的溶解和传递两个方面。 2.1 控制溶氧量(C*-CL)是氧溶解的推动力,控制溶氧量首要因素是控制氧分压(C*)。高密度培养往往采用通入纯氧的方式提高氧分压,而厌氧发酵则采用各种方式将氧分压控制在较低水平。如啤酒发酵,麦汁充氧和酵母接种阶段,一般要求氧含量达到8~10PPM;而啤酒发酵阶段,一般啤酒中的含氧量不得超过2PPM。 2.2控制氧传递速率氧传递速率主要考虑KLa的影响因素。从一定意义上讲,KLa愈大,好氧生物反应器的传质性能愈好。控制KLa的途径可分为操作变量、反应液的理化性质和反应器的

光谱仪的工作原理

光谱仪的工作原理-标准化文件发布号:(9556-EUATWK-MWUB-WUNN-INNUL-DDQTY-KII

光谱仪的工作原理元素的原子在激发光源的作用下发射谱线,谱线经光栅分光后形成光谱,每种元素都有自己的特征谱线,谱线的强度可以代表试样中元素的含量,用光电检测器将谱线的辐射能转换成电能。检测输出的信号,经加工处理,在读出装置上显示出来。然后根据相应的标准物质制作的分析曲线,得出分析试样中待测元素的含量。 表面轮廓仪介绍 表面轮廓仪 - 简介 表面轮廓仪LK-200M型表面轮廓仪采用广精精密最新的基于windows版本的测量软件,具有强大卓越的数据处理分析功能。测量时,零件装夹位置即使任意放置,也能得到满意的测量结果;即使需要测量长度为220mm的工件,测量软件也能保证其1μm的采样步长。 LK-200H型表面轮廓仪采用耐用可靠的16位A/D功能板,其极高的分辨率量程比(1/65536),用户即使需要大量程测量,仍能保持极高的测量精度。 LK-200M型表面轮廓仪采用工控计算机处理测量数据及仪器控制操作。其高质量、高可靠性及突出的防尘、防振、防油、防静电能力使广精精密用户将使用维护成本降至最低。 表面轮廓仪 - 原理 表面轮廓仪LK-200M型表面轮廓仪采用直角坐标法,传感器移动式。直线运动导轨采用高精度气浮导轨,作为测量基准; 电器部分由高级计算机组成;测量软件采用基于中文版Windows操作系统平台的系统测量软件,完成数据采集、处理及测量数据管理等工作。 表面轮廓仪 - 功能 角度处理:两直线夹角、直线与Y轴夹角、直线与X轴夹角 点线处理:两直线交点、交点到直线距离、交点到交点距离、交点到圆心距离、交点到点距离 圆处理:圆心距离、圆心到直线的距离、交点到圆心的距离、直线到切点的距离线处理:直线度、凸度、LG凸度、对数曲线 表面轮廓仪 - 技术规格 表面轮廓仪测量长度:≤200mm

pH计和溶氧分析仪的原理及特点

pH计和溶氧分析仪的原理及特点 1、pH计的工作原理 水的pH值随着所溶解的物质的多少而定,因此pH值能灵敏地指示出水质的变化情况。pH 值的变化对生物的繁殖和生存有很大影响,同时还严重影响活性污泥生化作用,即影响处理效果,污水的pH值一般控制在6.5~7之间。水在化学上是中性的,某些水分子自发地按照下式分解:H2O=H++OH-,即分解成氢离子和氢氧根离子。在中性溶液中,氢离子H+和氢氧根离子OH-的浓度都是10~7mol/l,pH值是氢离子浓度以10为底的对数的负数:pH=-log,因此中性溶液的pH值等于7。如果有过量的氢离子,则pH值小于7,溶液呈酸性;反之,氢氧根离子过量,则溶液呈碱性。 pH值通常用电位法测量,通常用一个恒定电位的参比电极和测量电极组成一个原电池,原电池电动势的大小取决于氢离子的浓度,也取决于溶液的酸碱度。该厂采用了CPS11型pH 传感器和CPM151型pH变送器。测量电极上有特殊的对pH反应灵敏的玻璃探头,它是由能导电、能渗透氢离子的特殊玻璃制成,具有测量精度高、抗干扰性好等特点。当玻璃探头和氢离子接触时,就产生电位。电位是通过悬吊在氯化银溶液中的银丝对照参比电极测到的。pH值不同,对应产生的电位也不一样,通过变送器将其转换成标准4~20mA输出。 2、溶氧分析仪的工作原理 水中的氧含量可充分显示水自净的程度。对于使用活化污泥的生物处理厂来说,了解曝气池和氧化沟的氧含量非常重要,污水中溶氧增加,会促进除厌氧微生物以外的生物活动,因而能去除挥发性物质和易于自然氧化的离子,使污水得到净化。

测定氧含量主要有三种方法:自动比色分析和化学分析测量,顺磁法测量,电化学法测量。水中溶氧量一般采用电化学法测量。该厂采用了COS4型溶氧传感器和COM252型溶氧变送器。氧能溶于水,溶解度取决于温度、水表面的总压、分压和水中溶解的盐类。大气压力越高,水溶解氧的能力就越大,其关系由亨利(Henry)定律和道尔顿(Dalton)定律确定,亨利定律认为气体的溶解度与其分压成正比。 以COS4氧量测量传感器为例,其中的电极由阴极(常用金和铂制成)和带电流的反电极(银)、无电流的参比电极(银)组成,电极浸没在电解质如KCl、KOH中,传感器有隔膜覆盖,隔膜将电极和电解质与被测量的液体分开,因此保护了传感器,既能防止电解质逸出,又可防止外来物质的侵入而导致污染和毒化。 相反电极和阴极之间施加极化电压,假如测量元件浸入在有溶解氧的水中,氧会通过隔膜扩散,出现在阴极上(电子过剩)的氧分子就会被还原成氢氧根离子: O2+2H2O+4e-? 4OH-。 电化学当量的氯化银沉淀在反电极上(电子不足):4Ag+4Cl-? 4AgCl+4e-。对于每个氧分子,阴极放出4个电子,反电极接受电子,形成电流,电流的大小与被测同污水的氧分压成正比,该信号连同传感器上热电阻测出的温度信号被送入变送器,利用传感器中存储的含氧量和氧分压、温度之间的关系曲线计算出水中的含氧量,然后转化成标准信号输出。参比电极的功能是确定阴极电位。COS4溶氧传感器的响应时间为:3分钟后达到最终测量值的90%,9分钟后达到最终测量值的99%;最低流速要求为0.5cm/s。 3、 pH计的特点

1 溶解氧对发酵的影响

1 溶解氧对发酵的影响 溶氧是需氧发酵控制最重要的参数之一。由于氧在水中的溶解度很小,在发酵液中的溶解度亦如此,因此,需要不断通风和搅拌,才能满足不同发酵过程对氧的需求。溶氧的大小对菌体生长和产物的形成及产量都会产生不同的影响。如谷氨酸发酵,供氧不足时,谷氨酸积累就会明显降低,产生大量乳酸和琥珀酸。 1.1 溶氧量在发酵的各个过程中对微生物的生长的影响是不同的 改变通气速率发酵前期菌丝体大量繁殖,需氧量大于供氧,溶氧出现一个低峰。在生长阶段,产物合成期,需氧量减少,溶氧稳定,但受补料、加油等条件大影响。补糖后,摄氧率就会增加,引起溶氧浓度的下降,经过一段时间以后又逐步回升并接近原来的溶解氧浓度。如继续补糖,又会继续下降,甚至引起生产受到限制。发酵后期,由于菌体衰老,呼吸减弱,溶氧浓度上升,一旦菌体自溶,溶氧浓度会明显上升。 1.2 溶氧对发酵产物的影响 对于好氧发酵来说,溶解氧通常既是营养因素,又是环境因素。特别是对于具有一定氧化还原性质的代谢产物的生产来说,DO的改变势必会影响到菌株培养体系的氧化还原电位,同时也会对细胞生长和产物的形成产生影响。[1] 在黄原胶发酵中,虽然发酵液中的溶氧浓度对菌体生长速率影响不大,但是对菌体浓度达到最大之后的菌体的稳定期的长短及产品质量却有着明显的影响。 [2] 需氧微生物酶的活性对氧有着很强的依赖性。谷氨酸发酵中,高溶氧条件下乳酸脱氢酶(LDH)活性明显比低溶氧条件下的LDH酶活要低,产酸中后期谷氨酸脱氢酶(GDH)的酶活下降很快,这可能是由于在高溶氧条件下,剧烈的通气和搅拌加剧了菌体的死亡速度和发酵活性的衰减。[3] DO值的高低还会改变微生物代谢途径,以致改变发酵环境甚至使目标产物发生偏离。研究表明,L-异亮氨酸的代谢流量与溶氧浓度有密切关系,可以通过控制不同时期的溶氧来改变发酵过程中的代谢流分布,从而改变Ile等氨基酸合成的代谢流量。[4] 2 溶氧量的控制

汽轮机凝结水溶解氧量高的原因分析及对策

汽轮机凝结水溶解氧量高的原因分析及对策 【关键词】凝结水,溶解氧,空气漏入,过冷度 【论文摘要】本文提出空气的漏入和凝结水过冷是凝结水溶解氧的原因,凝结水溶解氧影响机组经济性和安全性,并且是缓慢的过程,对此提出了对策,供运行和有关部门参考。 大机组随着参数、自动化程度的提高,对热力循环的工作介质的品质要求也越来越高,对汽轮机凝结水的水质要求的标准逐步提高,凝结水溶解氧量是表征凝结水水质的重要指标之一,下面对凝结水溶解氧量的机理、因素及技术发展进行分析,提出了采取的措施,供设计和运行维护参考。 凝汽器内除氧技术的发展:早先的中低压汽轮机的凝汽器热水井无除氧淋水装置和凝汽器冷却水管束布置不合理,蒸汽直接加热热水井凝结水效果不好等,随着对凝结水水质的要求越来越高,高压机组、超高压机组、亚临界机组凝汽器开始设置有淋水装置和汽轮机排汽直接加热凝结水的设计,来减少凝结水过冷,前苏联和美国电站广泛采用凝汽器鼓泡装置,并且近几十年来,研制了凝汽器加热凝结水的除氧装置和扫气式除氧装置。凝汽器内鼓泡装置,在热水井的凝结水被蒸汽鼓泡搅动而混合加热,凝结水被加热到饱和温度时,释放出非凝结气体,这种装置在低负荷启动和非正常工况下投运。加热凝结水的除氧装置是1984年2月Katsumoto ohtake等人提出快速去除凝汽器内凝结水中氧气的除氧装置,凝汽器内设有用隔板分割成明渠和暗渠,明渠中设有加热装置,凝结水先进入明渠被蒸汽加热,对凝结水除氧后流向暗渠,这种设施对全部凝结水加热,使除氧效果更好,除氧时间更短。扫气式除氧装置是日本Keizo ishida等人于1983年2月提出热水井除氧效果好和阻止氧气重新溶于凝结水的除氧装置,此结构是热水井和冷却水管之间安装两块倾斜上下错开的隔板,隔板固定凝汽器前后壁,凝结水沿此隔板曲折流动,热水井底部引入辅助蒸汽与凝结水流向相反,这样改善凝汽器除氧性能,并且除氧时间短。 1凝结水溶解氧原因分析 凝结水溶解氧的机理:由于凝汽器内空气进入和凝结水存在过冷,使凝结水中溶解氧,这就是凝结水溶解氧的机理。空气漏入量增加,凝结水溶解氧量增加,凝结水过冷度增加,凝结水溶解氧量也随之增加,如果空气不进入和过冷度为零,氧气在液体里的溶解度趋于零,因此凝汽器被设计成象除氧器那样,并且在满负荷时效果最佳,这是理想状态,影响凝结水溶解氧的两个因素是凝结水存在过冷度和空气的进入。 1.1 过冷的原因 凝结水过冷度表征凝汽器热水井中凝结水的过冷却程度,凝结水热水井出口凝结水温度与凝汽器在排汽压力下对应的饱和温度之差称为过冷度。现代装置对凝汽器要求其过冷度不超过0.5—1℃。过冷度增加,凝结水溶解氧量也随之增加,因此过冷度不仅影响低压给水系统的腐蚀,而且也影响凝汽器空气漏入量的估算,机组的经济性和安全性。 过冷的原因:由于蒸汽从排汽口向下部流动时产生阻力,造成下部蒸汽压力低于上部压力,下部凝结水温度较上部低,从而产生过冷,此外蒸汽被冷却成液滴时,在凝汽器冷却水管间流动,因液滴的温度比冷却水管管壁温度高,凝结水降温从而低于其饱和温度,产生过冷,以及空气漏入,空气分压力增大,蒸汽的分压力相对降低,蒸汽仍在自己的分压力下凝结,使凝结水温度低于排汽温度,产生过冷,如果抽气器不能及时抽出,增大了传热阻力,